Crash Cymbal Study: Measured Results With and Without Drum Baffles
Acoustics & Measurement · · Drum Baffles
The initial attack of a crash cymbal can be a prominent part of high-frequency spill reaching nearby microphones, musicians and audience positions. This selected-hit comparison examines that attack with clear 23- and 30-inch Drum Baffles, each compared against a matching no-baffle position. It focuses on targeted directional control, not a room-wide sound reduction rating.
The largest highlighted sample difference is 22.3 dB lower in the 16–20 kHz band during the first 2 ms of a selected crash hit with a 30-inch baffle. It is a band- and window-specific relative difference, not dB SPL or a general product rating.
In the same 16–20 kHz band, the 30-inch sample was 14.79 dB lower over the first 20 ms (14.8 dB rounded). The estimated full-band 2 ms RMS attack difference was 10.8 dB lower, versus 9.6 dB in the original raw full-band result. That estimate uses an assumed minimum-phase microphone correction. These are different analyses, not quantities to add.
Frequency-band attack comparison
Positive values mean lower than the matching no-baffle recording; negative values mean higher in that band and window. No baffle is the 0 dB reference. All differences are unweighted relative dB, not absolute SPL.
First 2 ms — 6 ft mic / 6 ft rear drywall
| Frequency band | No baffle reference (dB) | 23-inch relative reduction (dB) | 30-inch relative reduction (dB) |
|---|
| 4–6 kHz | 0 | -0.9 | -0.3 |
| 6–8 kHz | 0 | 7.6 | 3.9 |
| 8–12 kHz | 0 | 5.7 | 11.5 |
| 12–16 kHz | 0 | 14.7 | 19.8 |
| 16–20 kHz | 0 | 10.6 | 22.3 |
First 20 ms — 6 ft mic / 6 ft rear drywall
| Frequency band | No baffle reference (dB) | 23-inch relative reduction (dB) | 30-inch relative reduction (dB) |
|---|
| 4–6 kHz | 0 | 0.06 | 0.54 |
| 6–8 kHz | 0 | 1.78 | 3.42 |
| 8–12 kHz | 0 | 4.31 | 3.57 |
| 12–16 kHz | 0 | 8.24 | 10.18 |
| 16–20 kHz | 0 | 11.03 | 14.79 |
First 100 ms — 6 ft mic / 6 ft rear drywall
| Frequency band | No baffle reference (dB) | 23-inch relative reduction (dB) | 30-inch relative reduction (dB) |
|---|
| 4–6 kHz | 0 | 0.51 | -1.34 |
| 6–8 kHz | 0 | -0.08 | -1.3 |
| 8–12 kHz | 0 | 3.15 | 1.19 |
| 12–16 kHz | 0 | 6.12 | 5.54 |
| 16–20 kHz | 0 | 9.12 | 8.9 |
Timing sensitivity near the attack
The apparent size ranking depends on both band and onset alignment. In 16–20 kHz, moving the 2 ms window start by 0.50 ms changes the 23-/30-inch comparison from 10.6/22.3 dB to 17.3/16.9 dB. In 6–8 kHz, the original 7.6/3.9 dB becomes 7.5/8.1 dB at +0.25 ms. This is timing sensitivity, not a label swap or proof that one size always performs better.
| 2 ms window start | 23-inch, 16–20 kHz (dB) | 30-inch, 16–20 kHz (dB) |
|---|
| Fourth-hit onset | 10.6 | 22.3 |
| Onset + 0.25 ms | 11.5 | 21.8 |
| Onset + 0.50 ms | 17.3 | 16.9 |
Measured setup and analysis method
Highlighted setup: a 30-inch baffle between the cymbal and an audience-side, on-axis microphone. Cymbal to microphone: 6 ft. Cymbal to rear white-drywall wall: 6 ft. The room was untreated and indoors. Baffle spacing was not recorded.
Each condition uses its selected fourth isolated crash hit after three preparatory strikes, with manual moderate strike effort. Strike force was not instrumented. There is one selected event per condition and no repeated-hit averaging. Each baffle comparison uses its matching no-baffle position.
Microphone: UMIK-1, serial 720-6211, with 0-degree calibration file 7206211.txt. Actual waveform capture was QuickTime at 48 kHz, mono, 24-bit PCM—not calibrated REW SPL logging.
Post-analysis microphone magnitude correction was applied. Results are unweighted relative dB differences, with no A-weighting and no ambient subtraction. The full-band corrected RMS values are estimates that additionally depend on an assumed minimum-phase microphone correction.
Each analysis window starts at that recording’s own fourth-hit onset. A 2 ms window contains only 96 samples at 48 kHz and has roughly 500 Hz frequency resolution. Short-window alignment and strike variability affect readings.
No digital full-scale clipping was found according to the supplied study record. Fixed recording gain and operating-system processing were not independently verified. The supplied paper reports that source videos were audited against waveforms. The PDF, CSVs, original figure exports and edited silent comparison clip have been inspected here; the original MOV videos, waveform audio and calibration file are not included in this upload for independent source-waveform verification.
Geometry schematic (not to scale): rear wall → cymbal → baffle → audience-side microphone. Wall to cymbal d = 6 ft; cymbal to microphone r = 6 ft. Baffle spacing not recorded.
Full-band 2 ms RMS comparisons
Each row is a separate indoor geometry, compared with its own matching no-baffle position. Raw → estimated corrected values are full-band RMS reductions over the first 2 ms. The approximately 12 ft rear-boundary condition was still a reflective indoor room; it is not evidence of a treatment improvement or a basis for extrapolating to other distances. No defensible uncertainty interval was supplied.
| Rear boundary | Mic distance | 23-inch raw → estimated corrected (dB) | 30-inch raw → estimated corrected (dB) |
|---|
| 6 ft rear drywall | 3 ft | 4.8 → 5.1 | 8.1 → 9.0 |
| 6 ft rear drywall | 6 ft | 6.3 → 6.5 | 9.6 → 10.8 |
| Approximately 12 ft rear boundary | 3 ft | 7.7 → 8.8 | 7.7 → 9.0 |
Hypothesis: simplified rear-wall geometry
Hypothesis / simplified geometry model—not measured wall behavior. Let r be cymbal-to-microphone distance and d be cymbal-to-rear-wall distance. The idealized rear-wall reflected/direct energy ratio is q = (1 − α) × [r / (r + 2d)]², and the extra-path delay is 2d / c. These calculations assume c = 343 m/s and α = 0, an ideal wall.
| r (ft) | d (ft) | Calculated energy ratio q | Calculated delay (ms) |
|---|
| 3 | 6 | 0.04 | 10.7 |
| 6 | 6 | 0.1111 | 10.7 |
| 3 | 12 | 0.01235 | 21.3 |
This model omits other reflections, source and microphone directivity, and phase interference. It does not measure the actual wall’s absorption. Selecting a 2 ms window does not prove reflection-free sound. The q values are energy ratios, not measured baffle reductions.
Interpretation and scope
The strongest sample differences are in the early, high-frequency attack. That supports discussing attack and high-frequency spill control for this tested cymbal-to-baffle-to-receiver path. Longer-window and lower-band results are smaller or sometimes negative; the full table preserves those outcomes.
Targeted baffle placement addresses a particular path from a cymbal toward a microphone or person while leaving the kit open. A selected crash hit does not establish guaranteed vocal clarity, a percentage reduction in total sound, universal performance, or a rating for every baffle product and setup.
Listening comfort, fatigue and hearing safety motivate interest in cymbal control, but none was measured as a health outcome in this sample study. Drum Baffles are not presented here as certified hearing protection.
Drummer-side 23- and 30-inch listening samples have no matching no-baffle baseline, so no splash-back reduction or increase is claimed. The earlier whole-kit isolation-booth sample is excluded from these results.
Study provenance
Source: the owner-supplied 16-page white paper (visual edition November 8, 2026) and original-precision CSVs. The HTML values agree with these sources at the displayed precision. Charts are frequency-band attack comparisons generated from those values, not live REW RTA screenshots or reconstructed absolute spectra. This is a completed selected-event manufacturer sample comparison, not a repeated-hit average or an independent product certification.
White paper, original figures and sample documentation
Download the complete 16-page manufacturer sample study, visual edition November 8, 2026 (PDF, 1.56 MiB). Includes full captions, references, recording chain, sample scope and the conditional reflection hypothesis. The HTML page summarizes selected results; the paper and source CSVs retain additional setups and windows.
Download the complete white paper (16-page PDF)
Silent presentation clip — not a loudness demonstration
Download the silent presentation clip (MP4)
Five seconds showing separate no-baffle, 23-inch and 30-inch takes, approximately aligned at the selected fourth hit. This MP4 contains no audio track. It cannot demonstrate comparative loudness, equal strike force or sub-millisecond acoustic onset timing.
Presentation-only edits: the door and extreme room edge were removed from the wall background, and the official logo was composited. The laptop screens contain matching audio-derived, post-analysis frequency-band plots—not captured live RTA displays. These edits do not document an untreated-versus-treated room change. The supplied provenance states that original source recordings are preserved by the study author.
Original Figure 05: frequency-band attack comparison, not a live REW RTA screenshot. The selected 30-inch sample is 22.3 dB lower at 16–20 kHz over the first 2 ms; 14.8 dB lower in the same band over 20 ms. Unweighted, microphone-magnitude-corrected relative differences, not SPL or a general rating. This figure displays 6–20 kHz; the table above retains the complete 4–20 kHz range, including negative results.
Original Figure 15: the same 6 ft microphone / 6 ft rear-drywall recordings with shifted analysis windows, not new physical tests. Size rankings change with onset alignment. Original-onset and +0.25/+0.50 ms values are retained in the table above; the source CSV also includes earlier starts and +1 ms.
Source data and provenance
Download the supplied CSVs unchanged at their original precision. HTML band values use one decimal for 2 ms and two decimals for 20/100 ms; full-band and timing summaries use one decimal. The supplied paper and these summaries agree at that precision. The model CSV contains assumed/proxy inputs and fitted predictions, not additional measured results.
This upload includes the finished paper, figure exports, CSVs, edited presentation stills and silent clip. Original MOV videos, retained waveform audio and calibration file 7206211.txt are referenced in the paper but are not included here. The website has not independently repeated the source-waveform audit. Video-frame source times in the media provenance are distinct from the approximate acoustic-onset times listed on page 15.
Read the general acoustic measurement guide · Acoustics & Measurement